Reverse Osmosis Restoration
Replacement Modules - Restored and New
|
Luxx Ultra-Tech's proprietary restoration process will save RO system users up to 50% in maintenance costs, over the cost of purchasing new filters. Restored modules will operate as efficiently as a new module, at half the cost of a new purchase. |
Following Is a Case Study and Analysis of a Typical 8" x 40" Restored Membrane Module
| PARAMETERS | PRE-RESTORATION | POST-RESTORATION |
| Primary Pressure (psig) Final Pressure (psig) Differential Pressure (psig) |
200 199 1 |
200 199 1 |
| Permeate Flow (gpm) Concentrate Flow (gpm) |
2.2 40 |
5.5 40 |
| Feed Conductivity (umhos) Permeate Conductivity (umhos) |
2000 25 |
1500 8 |
| % Rejection | 98.75 | 99.46 |
Some of the membranes Luxx Ultra-Tech can restore,
or provide new replacement modules for:
Tri-Sep®, DeSal®, Film Tec®, Dow®, Fluid Systems®*,
Hydrautics®, Osmonics®, Toray®, & others
* Trademark of Koch Membrane Systems